REQUIRED TOOLS
- Screwdriver T10 Torx head
- Screwdriver T25 Torx head
- Allen key #5
BEFORE YOU START

| - Before you start, make sure the device is turned off and disconnected!
|
PROCEDURE

- Unscrew the 2 screws of the pitcher holder base with a Torx T10 screwdriver. Remove the pitcher holder base from the Moose.

- Unscrew the 2 screws on the front of the Greg housing with an Allen key #5.

- Unscrew the 4 screws at the back of the Greg housing with a Torx T25 screwdriver.
- Move the steam wand up.
- Remove the Greg housing front from the Moose by holding the housing front with 2 hands.
- Pull the housing to the front until it almost touches the side of the RFID holder.
- Lift the housing upwards until it is above the RFID holder.
- Pull the housing to the front to fit the steam wand through the slit.

You can find the article to close the Greg housing by clicking here.