REQUIRED TOOLS
- Screwdriver T10 Torx head
- Screwdriver T25 Torx head
- Allen key #5
BEFORE YOU START

| - Before you start, make sure the device is turned off and disconnected!
|
PROCEDURE
- Move the steam wand up to the top.

- Carry the Greg housing with 2 hands and fit the steam wand through the slit of the housing.
- Push the housing to the back. Take care that the housing doesn't touch the RFID holder.
- Move the housing downwards to fit the RFID holder through the housing.
- Push the housing backwards until it locks in the Greg housing back assembly. Check the alignment of the touchscreen in the housing! If needed, pull the touchscreen downwards with 2 fingers to align it in the housing of the Moose.
- Screw the 4 black T25 Torx screws in the back of the Moose and the 2 Hex #5 socket cap screws on the front of the housing.
- WARNING the tightening force of the screw is max 1Nm!
- Place the pitcher holder base on top of the RFID holder.
- Screw the 2 T10 Torx screws in the pitcher holder base.
- Put pitcher holder (Greg or Epic Greg) on the pitcher holder base.
- Turn the pitcher holder until it is flush with the housing of the Moose.
- Plug in the electrical cord and turn the Moose on.
- Check the calibration of the load cell
- Check all the valves in the manual testing menu
You can find the article to open the Greg housing by clicking here.